BE/HR-E-IIB

Deflagration Flame Arrester, endurance burning proof, End-of-Line

  • endurance burning protection for alcohols and hydrocarbons up to explosion group IIB
  • specially developed for sea going vessels but also useful for inland navigation vessels and on shore systems
  • weather hood protects against environmental impact (i.e. weather, bird nests, etc.)
  • weather hood opens and signals the impact of a flame
  • fusible link is resistant against
  • modular design allows replacement of single FLAMEFILTER®
  • protection against atmospheric deflagration and endurance burning
  • modular design results in low spare part cost

Function and Description

The PROTEGO® BE/HR-E-IIB consists of a housing (1), a weather hood (2) and the PROTEGO® flame arrester unit (3). During normal operation, the metal weather hood is in a closed position. If a flame burns on the flame arrester element surface, the fusible link (5), located in a center position, will melt and let the spring loaded weather hood move into the open position. The PROTEGO® flame arrester unit consists of two FLAMEFILTER® discs (4), which are installed in a FLAMEFILTER® casing. The PROTEGO® BE/HR-E end-of-line deflagration flame arrester is available for hydrocarbons for explosion group IIB (MESG ≥ 0,5 mm) and alcohols.

The standard design can be used for operating temperatures up to +60°C / 140°F.

Type-approved in accordance with ATEX Directive and EN ISO 16852 as well as other international standards. Approved according to IMO MSC/Circular 677 as well as IMO MSC.1/Circular 1324 and 1325.

Dimensions

To select the nominal size (DN), please use the flow capacity charts on the following pages

DN80 / 3"100 / 4"
a353 / 13.90353 / 13.90
b250 / 9.84250 / 9.84
Dimensions in mm / inches Dimensions for Deflagration flame arrester with heating jacket upon request

Material selection for housing

Design BC
HousingSteelStainless Steel
Weather HoodSteelStainless Steel
Flame arrester unitAA, C
Special materials upon request

Material combinations of flame arrester unit

DesignAC
FLAMEFILTER® cageStainless SteelStainless Steel
FLAMEFILTER®Stainless SteelHastelloy
SpacerStainless SteelHatelloy
Special materials upon request

Selection of explosion group

MESGExpl. Gr. (IEC / CEN)Gas Group (NEC)
≥ 0,5 mmIIBB
Special approvals upon request

Flange connection type

EN 1092-1; Form B1
ASME B16.5 CL 150 R.F.
other connections upon request

Flow Capacity Chart

The flow capacity charts have been determined with a calibrated and TÜV certified flow capacity test rig. Volume flow V in (m³/h) and CFH refer to the standard reference conditions of air ISO 6358 (20°C, 1bar). For conversion to other densities and temperatures refer to Sec. 1: “Technical Fundamentals”.