Vacuum Relief Valve

  • 10% technology for minimum pressure increase up to full lift
  • extreme tightness, resulting in lowest possible product losses and reduced environmental pollution
  • set pressure close to opening pressure for optimum pressure maintenance in the system
  • high flow capacity
  • valve pallet is guided inside the housing to protect against harsh weather conditions
  • can be used in explosion hazardous areas
  • automatic condensate drain
  • best technology for API tanks

Función y Descripción

The SV/E-1-0 type PROTEGO® valve is a highly developed vacuum relief valve with excellent flow performance. It is primarily used as a device for relieving vacuum in tanks, containers, and process engineering equipment. The valve offers reliable protection against vacuum and prevents in-breathing of air close to the set pressure.

The device will start to open as soon as the set pressure is reached and only requires 10% overpressure to reach full lift. Continuous investments in and a commitment to research and development have allowed PROTEGO® to develop a low pressure valve which has the same opening characteristics as a high pressure safety relief valve.

This “full lift type” technology allows the valve to be set at just 10% below the maximum allowable working pressure of the tank and still safely vent the required mass flow.

Due to our highly developed manufacturing technology, the tank pressure is maintained up to set pressure with a tightness that is far superior to the conventional standard. This feature is achieved by valve seats made of high quality stainless steel and with precisely lapped valve pallets (1) or with an air cushion seal (2) in conjunction with high quality FEP diaphragm. The valve pallets are also available with a PTFE seal to prevent the valve pallets from sticking when sticky products are used, and they enable the use of corrosive substances. After the vacuum is released, the valve reseats and provides a tight seal again.

Dimensiones

To select the nominal size (DN), use the flow capacity chart on the following page

DN50 / 2"80 / 3"100 / 4" 150 / 6" 200 / 8" 250 / 10" 300 / 12"
a140 / 5.51170 / 6.69190 / 7.48230 / 9.06300 / 11.81325 / 12.80425 / 16.73
b75 / 2.9585 / 3.3595 / 3.74120 / 4.72140 / 5.51165 / 6.50205 / 8.07
c205 / 8.07205 / 8.07285 / 11.22360 / 14.17405 / 15.94460 / 18.11500 / 19.69
d170 / 6.69235 / 9.25280 / 11.02335 / 13.19445 / 17.52505 / 19.88505 / 19.88
e215 / 8.46215 / 8.46255 / 10.04335 / 13.19425 / 16.73460 / 18.11625 / 24.61
Dimensiones en mm / pulgadas Dimensions for vacuum relief valve with heating jacket upon request

Selección de materiales para la vivienda

Design - B CD
Housing-SteelStainless SteelAluminium
Heating jacket (SV / E-1-0-H...)--
Stainless Steel-
Valve seat-Stainless SteelStainless SteelStainless Steel
Sealing-PTFEPTFEPTFE
Option: Housing with ECTFE-lining Design D and Special materials upon request

Selección de materiales para la válvula de vacío

Design ABCDEF
vacuum range [mbar]
[inch W.C.]
-2,0 up to -3,5
-0.8 up to -1.4
<-3,5 up to -14
<-1.4 up to 5.6
<-14 up to -35
<-5.6 up to -14
<-35 up to -60
<-14 up to -24
<-14 up to -35
<-5.6 up to -14
<-35 up to -60
<-14 up to -24
Valve palletAluminiumStainless SteelStainless SteelStainless SteelStainless SteelStainless Steel
SealingFEPFEPMetal to MetalMetal to MetalPTFEPTFE
Special materials(Alu-coated, Titanium, Hastelloy) and higher vacuum settings upon request

Tipo de bridas de conexión

EN 1092-1; Form B1
ASME B16.5 CL 150 R.F.
other types upon request

Modelo y especificación

The valve pallet is weight-loaded. Higher vacuum can be achieved upon request with a special spring-loaded design.
There are two different designs:

Vacuum valve in basic design

SV/E-1-0 - –

Vacuum valve with heating jacket

SV/E-1-0 - H

Additional special devices available upon request.

Settings

Vacuum: -2.0 mbar -60 mbar
-0.8 inch W.C. -24 inch W.C.
Higher vacuum settings upon request.

Diagrama de flujo volumétrico

Los diagramas de flujo volumétrico han sido determinados con un banco de pruebas de caudal calibrado y certifi - cado por TÜV. El flujo volumétrico V. en [m³/h] y el CFH se refi eren a las condiciones estándar de referencia de aire según ISO 6358 (20°C, 1bar). La conversión a otras densidades y temperaturas están referidas en el Vol. 1: “Fundamentos Técnicos”.